JG45HD/JG55 – (Financial Security Edition) Enhanced/ Acoustic Wave Resistance Control System

JG45HD/JG55 – Enhanced/ Acoustic Wave Resistance Control System
Black control panel with buttons and a larger connected device.
📋 Acoustic Deterrence System – Technical Specifications Sheet (Financial Security Edition)
Note: Parameters are derived from actual field measurements of JG45HD and JG55HD models and fully comply with China’s financial industry security standards.
🔊 I. Core Acoustic Performance Parameters
Parameter
JG45HD (Standard Model)
JG55HD (Enhanced Model)
Financial Scenario Adaptation Notes
Sound Pressure Level (SPL)
131 dB ±2 dB @ 1 m
134 dB ±2 dB @ 1 m
≥130 dB recommended for vaults/ATM zones (effective deterrent range >30 m)
Beam Angle
30° @ –3 dB
20° @ –3 dB
Narrow beam ensures precise targeting—minimizes collateral impact on customers/residents
Frequency Range
2.5–5.0 kHz
2.0–6.0 kHz
Optimized for human auditory sensitivity; high penetration (through glass, rain, light fog)
Acoustic Modes
1 fixed mode (high-intensity tone)
5 programmable modes:
① Voice announcement
② Warning tone
③ Deterrence tone
④ Custom audio
⑤ Mute mode
Essential for financial workflows:
Voice → Warning → Deterrence
escalation protocol
Voice Storage
SD card (up to 64 GB)
SD card (up to 128 GB)
Supports multilingual announcements (Mandarin, English, regional dialects); all content pre-approved by legal/compliance teams
⚙️ II. Electrical & Mechanical Parameters
Security system with alarms in various critical facilities.
Parameter
JG45HD
JG55HD
Financial Compliance Highlights
Rated Power
70 W
100 W
Low-power design compliant with banks’ green energy policies
Power Input
AC 220 V ±10%, 50 Hz
AC 220 V ±10%, 50 Hz
Dual power supply: mains + optional PoE
Backup Power
Not available
Built-in lithium battery (36 Wh)
≥60 min operation during power outage (
mandatory for vaults/data centers
)
Standby Duration
≥7 days (low-power mode)
Fully supports 7×24 unattended operation
Ingress Protection (IP)
IP54
IP66
JG55HD: Dust- and water-resistant—suitable for outdoor ATM kiosks
Operating Temperature
–10°C to +50°C
–20°C to +60°C
Reliable performance in northern winters & southern high-humidity environments
Tamper Resistance
None
Physical tamper-proof housing + integrated alarm trigger
Auto-alerts central platform upon physical breach (
complies with GA 38–2021
)
Dimensions (L×W×H)
280 × 180 × 150 mm
320 × 220 × 180 mm
Concealed mounting design—avoids alarming customers
Unit Weight
2.5 kg
5.1 kg
Mounting bracket rated for ≥10 kg load (wind/earthquake resistance)
🌐 III. Intelligent Control & Integration Capabilities
Function Module
JG45HD
JG55HD
Financial Platform Integration Value
Network Control
Supported (TCP/IP)
Supported (TCP/IP + optional 4G module)
Centralized remote management across all branch locations
Protocol Support
ONVIF, GB/T 28181, RTSP
ONVIF, GB/T 28181, RTSP, SDK/API
Seamless integration with:
• Bank-owned security platforms
• Hikvision/Dahua NVRs
• Smart Finance Cloud Platforms
Inter-system Linkage
Basic linkage with video, access control, alarms
Multi-source intelligent linkage:
• AI video analytics (crowd gathering, perimeter climbing)
• Abnormal door access events
• PIR/radar detector triggers
Enables closed-loop response:
Perceive → Alert → Intervene
Access Control
Single-level password
Three-tier role-based permissions:
• Operator
• Administrator
• Auditor
Meets internal control & audit requirements per financial regulators
Operation Logs
Local storage only (7 days)
Cloud-synced + local dual backup (≥180 days)
Full audit trail—admissible as judicial evidence
Emergency Stop
Remote-only (via platform)
Dedicated physical emergency stop button (on controller)
One-touch deactivation—mitigates legal liability risks
📱 IV. Controller Specifications (Optional)
Item
JG45 Controller
JG55 Controller
(Financial Recommendation)
Button Functions
Weak pulse, Strong pulse
Weak pulse, Strong pulse, Emergency stop (dedicated physical key)
Display
LED status indicators
2.4-inch LCD screen (real-time display of mode, battery level, system status)
Communication
Wired (RS485)
Wired + 2.4 GHz wireless (≤150 m range)
Weight
0.8 kg
0.9 kg
Financial-Specific Features
Dual-person authorization: High-intensity mode requires simultaneous press of two keys
✅ V. Financial Industry Compliance Certifications
Network expansion system diagram with acoustic barriers and controllers.
Certification Type
Scope / Requirements
Applicable Scenarios
National Certifications
CCC, CE, RoHS
Mandatory for all deployment scenarios
Security Standards
Compliant with GA 38–2021
"Security Protection Requirements for Banking Business Premises"
, Clause 5.3.4 (acoustic-optic alarm devices)
Vaults, cash handling areas, ATM machine rooms
Acoustic Compliance
Directional beam technology ensures ≤55 dB noise in non-target zones (
per GB 22337–2008
)
Branch lobbies, community banking outlets (prevents public complaints)
Data Security
AES-128 encrypted communications; tamper-proof operation logs
Complies with
"Financial Data Security Classification Guidelines"
Privacy Protection
Precision beam control prevents sound spillover into residential/commercial zones
Critical for urban branch deployments
💡 VI. Rapid Deployment Reference Guide – Financial Scenarios
Scenario
Recommended Model
Key Configuration
Compliance Requirements
Bank Branch Lobby
JG45HD
Volume capped at ≤85 dB (for routine announcements); voice script:
“Please maintain safe distancing.”
Beam angled downward 15°—avoid customer waiting areas
Vault / Cash Processing Area
JG55HD
Redundant dual-unit deployment; linked with vibration sensors + AI video analytics
≥60 min battery backup; mandatory tamper alarm
ATM Machine Room Perimeter
JG55HD
IP66-rated + optional solar power; beam directed inward along perimeter fence
Automatic mute mode activated nightly (22:00–06:00)
Data Center Entry/Exit
JG55HD
Deep integration with access control system; three-stage acoustic intervention protocol
Operation logs synced to SOC (Security Operations Center)
Branch Command Center
JG55 Controller
Centralized management of all devices; large-screen visual interface
Dual-person authorization enforced; audit logs retained ≥180 days
📌 Deployment Notes:
  • All voice content must be reviewed and formally approved by the bank’s Legal & Compliance Department prior to deployment.
  • Beam direction and coverage must be validated in situ “Environmental Noise Emission Standards for Social Living Areas”
  • Quarterly functional verification and battery health diagnostics are strongly recommended.
  • Operators must complete specialized training and sign the “Acoustic Device Usage Accountability Agreement”
Contact
Leave your information and we will contact you.
WhatsApp
Wechat