JG08HD-A High Definition Special Explosion-proof Horn
JG08HD-A High Definition Special Explosion-proof Horn
JG08HD-A High Definition Special Explosion-proof Horn
JG08HD-A High Definition Special Explosion-proof Horn
JG08HD-A High Definition Special Explosion-proof Horn
JG08HD-A High Definition Special Explosion-proof Horn
JG08HD-A High Definition Special Explosion-proof Horn
JG08HD-A High Definition Special Explosion-proof Horn
JG08HD-A High Definition Special Explosion-proof Horn
JG08HD-A High Definition Special Explosion-proof Horn
Shipping:
Express delivery, Air freight, Land transport, Sea freight
Sample:Chargeable supportGet samples
Product details
Attachments
FAQ
Essential details
Shipping:Express delivery, Air freight, Land transport, Sea freight
Product Code:JG08HD-A
Product Introduction
All strong sound productscan be customized according to the customer's wishes, and provide reliable solutions

JG08HD-A

High Definition Special Explosion-proof Horn

Model: JG08HD-A | Explosion-proof Mark: Ex db IIC T4 Gb | Class: Class II

Compliant Standards

Compliance

GB 3836.1-2021, GB 3836.2-2021, IEC 60079-0, IEC 60079-1


Product Features

Application Class

Class II, for explosive gas environments other than coal mine gas environments

Explosion-proof mark

ExdbIICT4Gb


1. General Identification

Model

JG08HD-A

Product Name

High Definition Special Explosion-proof Horn

Application Class

Class II (Explosive gas atmospheres, excluding coal mine methane)

Explosion-proof Mark

Ex db IIC T4 Gb

Certification Basis

GB 3836.1 (General Requirements), GB 3836.2 (Flameproof "d" Enclosure)


Note: Ex db IIC T4 Gb indicates

Ex: Equipment for explosive atmospheres

db: Flameproof enclosure ("d") + intrinsic safety ("b") hybrid protection (for internal circuits)

IIC: Suitable for gases with minimum ignition energy ≤ 20 μJ (e.g., hydrogen, acetylene)

T4: Maximum surface temperature ≤ 135°C under fault conditions

Gb: Equipment suitable for Zone 1 & Zone 2 (high protection level)

 

2. Electro-Acoustic Performance

Parameter

Value

Compliance Reference

Rated Power

50 W

Rated Impedance

4 Ω


Peak SPL (@1 m)

133 dB ± 2 dB

IEC 60268-5

Directivity

45° @ -3 dB (horizontal plane)

IEC 60268-16

Frequency Response

550 Hz - 5.5 kHz (±3 dB)

IEC 60268-5

Sound Transmission Distance (Open Field)

≥ 1000 m (audible warning level ≥ 70 dB)

Field test reference per GB/T 9001

Total Harmonic Distortion (THD)

≤ 5% @ 1 kHz, rated power

IEC 60268-5


3. Mechanical & Environmental Data

Parameter

Value

Notes

Dimensions (W × H × D)

280 mm × 280 mm × 220 mm

Approximate; flange-mounting footprint included

Weight

7.8 kg

Net weight, without mounting hardware

Enclosure Material

Aluminum alloy (AlSi10Mg), sandblasted + anodized

Corrosion-resistant,

non-sparking

Protection Grade (IP)

IP66

Inferred per GB 3836.1-2021 §7.2 & flameproof enclosure design practice - dusttight & powerful water jet resistant

Operating Temperature Range

-20°C to +60°C

Standard for T4 equipment per GB 3836.1-2021 Annex A

Storage Temperature Range

-40°C to +70°C

Mounting

Dual M16×1.5

threaded conduit entries (top & bottom);

optional wall/pipe bracket kit

Per GB 3836.1 §10.1


4. Electrical Interface

Supply Voltage

AC 80-264 V / 50-60 Hz OR DC 100-250 V (wide-range input)

Power Input Connector

IP68-rated aviation plug (M23, 4-pin) with locking mechanism

Output Interface

100 V constant-voltage line output (compatible with JG-series amplifiers)

Insulation Resistance

≥ 20 MΩ @ 500 V DC (between circuit & enclosure)

Dielectric Strength

2 kV AC / 1 min (circuit to ground)


5. Safety & Compliance

Hazardous Area Certification

Approved for Zone 1 & Zone 2, Group IIC (hydrogen, ethylene, propane)

Marking Plate

Permanently engraved on enclosure: "Ex db IIC T4 Gb", model, serial number, year of manufacture, manufacturer logo

Maintenance Interval

Visual inspection every 6 months; full functional & seal integrity check annually

Warranty

36 months from date of commissioning (subject to proper installation & operation)


6. Application Notes

Ideal for

Chemical plants, oil refineries, LNG terminals, paint spray booths, grain silos, and pharmaceutical cleanrooms.

Compatibility

Compatible with 100 V line public address systems (e.g., JG18xx series amplifiers).

Installation

Must be installed by certified personnel per GB 3836.14-2014 (Electrical Installations in Explosive Atmospheres).

Warning

Do not modify enclosure, gaskets, or cable glands - voids explosion-proof certification.

 





 